Hettich Rotanta 460 R Refrigerated Lab Centrifuge for High-Throughput Screening

11723L900_SKID $8,999.99

The ROTANTA 460 R enables efficient centrifugation in research and analytical laboratories. The centrifuge enables centrifugation times to be reduced substantially and is a reliable workhorse for high sample volumes and ideal for high-throughput screening. Its high-performance cooling ensures that the selected temperature is maintained.

An RCF of 6,446 can be achieved in a swing-out rotor and a value of 24,400 in an angle rotor. The temperature can be set to any value in the range -20 °C to +40 °C (-4 °F to +104 °F). The centrifuge additionally has stand-by cooling. Its outstanding performance, reliable cooling and comprehensive range of accessories make this centrifuge the ideal choice for routine centrifugation runs.

Its maximum capacity of three litres per run makes it a valuable tool in clinics and analytical laboratories, as well as the R&D sections of life science institutions. A large range of accessories is available for high-throughput screening of novel substances in research laboratories.

The ROTANTA 460 R is valued in the fields of biotechnology, microbiology and throughout the pharmaceutical industry because of its autoclavable and aerosol-tight accessories. The centrifuge has a rotor with a maximum RCF of 6,446 for the centrifugation of filter plates.

  • Max. capacity: in a swing-out rotor:
    4 x 750 ml
  • in an angle rotor:
    6 x 250 ml
  • Max. speed (RPM):
    15,000
  • Max. RCF:
    24,400
  • Dimensions (H x W x D):
    456 x 770 x 706 mm
  • Weight:
    approx. 141kg
  • Refrigeration:
    Infinitely variable from 20 °C to + 40 °C
  • Frequently used rotors:
    Swing-out rotor for 4 x 750 ml (90°), max. RCF 5,063 Cat. No. 5699
  • Angle rotor for 30 x 1.5 / 2 ml (45°), max. RCF 24,400 - Cat. No. 4489-A
  • Swing-out rotor for max. 12 microtitre plates (90°), max. RCF 6,446 - Cat. No. 5622
  • ROTANTA 460 R, without rotor, Cat. No. 5660
  • High speeds with fixed-angle rotors:
  • 24,400 RCF at a capacity of 30 x 1.5 / 2.0 ml

    18,038 RCF at a capacity of 6 x 94 ml

    14,025 RCF at a capacity of 6 x 250 ml

  • High capacities in swing-out rotors

4 x 750 ml at a max. RCF of 4,779

24 microtitre plates / 4 filter plates at a max. RCF of 4,211 or

12 microtitre plates / 2 filter plates at a max. RCF of 6,446

120 blood collection tubes at a max. RCF of 4,637

  • Comprehensive range of accessories
  • Easy to operate thanks to the C control panel
  • The temperature can be set to any value in the range -20 °C to +40 °C (-4 °F to +104 °F)
  • Stand-by cooling
  • Motor-driven lid locking

 

Freight shipment. Must be shipped to commercial address within the continental US.

 

 


Orders are shipped same day Monday-Friday before 4pm ET. Orders placed afterwards will be shipped the following business day. *excludes all USPS holidays **does not apply to ThorWoods handmade products, processing time located within the description ***does not apply to orders shipped LTL Freight, handling time may vary